support

24/7 Support

0333 565 2662

Fast Shipping

All Pakistan

Fast Shipping


   

How to Fix Gree AC Common Error Codes?

Gree air conditioners are renowned for their performance and durability, but occasional error codes can arise. This guide provides a comprehensive list of Gree AC error codes in Pakistan, their meanings, possible causes, and solutions to help you troubleshoot and resolve any issues.

Important Note: Before attempting any DIY fixes, always turn off your AC and disconnect the power supply for safety. If you’re unsure, consult a qualified technician.

E Series Error Codes #

Error Code Meaning Possible Cause Solution
E1 High-pressure protection activated Overheating, dirty condenser coils, faulty compressor Clean condenser coils, check for obstructions, consult technician if needed.
E2 Anti-freezing protection activated Low refrigerant, faulty temperature sensor Check refrigerant levels, replace temperature sensor if faulty.
E3 Low refrigerant Refrigerant leak Contact a technician to find and fix the leak, then recharge the system.
E4 Compressor exhaust temperature protection activated Overheating, dirty condenser coils Clean condenser coils, check for obstructions.
E5 Overcurrent protection activated Electrical issue, faulty wiring Check wiring and components, consult a technician if needed.
E6 Communication error between indoor and outdoor units Loose wiring, faulty control board Check wiring and control board, replace faulty components.
E8 Indoor fan motor or indoor circuit board malfunction Faulty motor or circuit board, loose connections Check motor and circuit board, tighten connections, replace faulty parts.
E9 Water flow switch issue Blocked drain pipe, faulty water flow switch Clear drain pipe, replace switch if faulty.
EE/ee Error loading data into EEPROM memory Faulty EEPROM chip Replace EEPROM chip.
EU IPM (Intelligent Power Module) overheating Overloaded IPM, faulty IPM Reduce load on IPM, replace if faulty.

F Series Error Codes #

Error Code Meaning Possible Cause Solution
F0 Low refrigerant level Refrigerant leak Contact a technician to find and fix the leak, then recharge the system.
F1 Indoor ambient temperature sensor open or short circuit Faulty sensor or wiring Replace sensor or repair wiring.
F2 Indoor evaporator temperature sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
F3 Outdoor ambient temperature sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
F4 Outdoor pipe temperature sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
F5 Exhaust temperature sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
F6 Overload limit or frequency drop issue Overloaded system, faulty components Reduce load on system, check components, consult a technician.
F8 Overcurrent limit or frequency drop issue Electrical issue, faulty components Check electrical connections and components, consult a technician.
F9 High exhaust temperature limit causing frequency drop Overheating, dirty condenser coils Clean condenser coils, check for obstructions.
FA Over-temperature of the tube causing frequency drop Overheating, faulty components Check components, consult a technician.
FC Door malfunction Obstruction, faulty door switch Remove obstruction, replace switch if faulty.
FE Compressor overload sensor malfunction Faulty sensor or compressor Replace sensor or compressor.
FH Anti-freezing limit reached, causing frequency drop Low ambient temperature, faulty sensor Check ambient temperature, replace sensor if faulty.

H Series Error Codes #

Error Code Meaning Possible Cause Solution
H0 Anti-high temperature limit reached in heating mode Overheating, faulty sensor Check for obstructions, replace sensor if faulty.
H1 Defrosting in progress Normal operation No action needed.
H2 Clearing static and dust buildup Normal operation No action needed.
H3 Compressor overload protection Overheating, faulty compressor Check for obstructions, replace compressor if faulty.
H4 Outdoor unit condensing pressure too high Blocked or inefficient heat exchanger Clean or replace heat exchanger.
H5 Input voltage incorrect, cables, compressor coil resistance, or insulation issues Faulty components, incorrect wiring Check wiring and components, correct voltage if needed.
H6 Indoor fan blocked or no feedback from motor Obstruction, faulty motor Remove obstruction, replace motor if faulty.
H7 Compressor operational steps/stages lost Faulty compressor or control board Replace compressor or control board.
HC PFC (Power Factor Correction) protection activated Faulty PFC module or sensor Replace module or sensor.
HE Compressor demagnetization protection activated Faulty compressor Replace compressor.

L Series Error Codes #

Error Code Meaning Possible Cause Solution
L3 Outdoor fan motor malfunction Faulty motor Replace motor.
LC Device not starting up Power supply issue, faulty board Check power supply and board, replace parts.
LD Compressor shutting down due to missing power phase Electrical issue, faulty compressor Check wiring and compressor, consult technician.
LE Compressor shutting down due to stuck rotor Faulty compressor Replace compressor.

P Series Error Codes #

Error Code Meaning Possible Cause Solution
P0 Drive module reset issue Faulty drive module Replace drive module.
P5 Compressor shutting down due to overcurrent in one phase Faulty compressor Replace compressor.
P6 Communication error between main and driver boards Faulty boards or wiring Check wiring and boards, replace parts.
P7 IPM (Intelligent Power Module) sensor circuit malfunction Faulty sensor or IPM Replace sensor or IPM.
P8 IPM overheating Overloaded IPM, faulty IPM Reduce load on IPM, replace if faulty.
PA Protection against excessive AC current from input Electrical issue, faulty parts Check wiring and components.
PC Current detection circuit or current sensor malfunction Faulty sensor or circuit Replace sensor or circuit.
PH Protection against high PN voltage Electrical issue, faulty parts Check wiring and components.
PL Protection against low PN voltage Electrical issue, faulty parts Check wiring and components.
PU Capacitor charging issue Faulty capacitor Replace capacitor.

U Series Error Codes #

Error Code Meaning Possible Cause Solution
U1 Compressor phase current detection circuit malfunction Faulty circuit or compressor Replace circuit or compressor.
U2 Compressor phase loss protection Electrical issue, faulty compressor Check wiring and compressor, consult technician.
U3 Protection against PN voltage drop Electrical issue, faulty parts Check wiring and components.
U4 Reverse running protection for compressor Faulty compressor or wiring Check wiring and compressor.
U5 AC current detection circuit malfunction Faulty circuit Replace circuit.
U7 Abnormal 4-way valve reversal Faulty valve or wiring Check wiring, replace valve if faulty.
U8 Exhaust temperature sensor disconnected Loose connection, faulty sensor Check connection, replace sensor if faulty.
U9 Error detecting zero voltage in AC power supply Power supply issue Check power supply.

Other Error Codes #

Error Code Meaning Possible Cause Solution
oE High temperature in PFC module or PFC module sensor malfunction Faulty module or sensor Replace module or sensor.
b5 Inlet tube sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
b7 Outlet tube sensor malfunction Faulty sensor or wiring Replace sensor or repair wiring.
C5 Jumper cap malfunction Faulty jumper cap Replace jumper cap.
C5 Connector jumper malfunction Faulty connector jumper Replace connector jumper.

I hope this comprehensive guide helps you troubleshoot your Gree AC error codes in Pakistan effectively!

Don’t Let AC Errors Spoil Your Comfort – Upgrade to a New Gree Today! #

After reading this FAQ, you’ll be well-equipped to troubleshoot any common Gree AC error codes in Pakistan. But if you’re looking to upgrade your AC or simply want to browse our latest models, we encourage you to visit our Gree AC products list page today!

We offer a wide range of Gree ACs to suit your needs and budget, and our friendly customer service team is always happy to help you choose the perfect AC for your home.

Easy monthly installment plans: #

We understand that buying a new AC can be a significant investment. That’s why we offer easy monthly installment plans with 0% down payment for up to 12 months. This makes it easier to afford a Gree AC and start enjoying the comfort of cool air in your home.

Explore our collection today: #

We’re confident that you’ll find the perfect Gree AC for your home in our extensive collection. So don’t wait any longer, explore our Gree AC products list page today and find the perfect AC for your needs!

Leave a Reply

Shopping cart
My account
0 items Cart
0 Wishlist
0 Compare